Arctic King Air Conditioner Troubleshooting [Step By Step Guide]

The Arctic King air conditioner is a leading brand for air conditioners. The AC has been a big hit due to its great cooling and durability. If you’re having problems with this air conditioner, here is how to troubleshoot it.

If you’re in the market for a new air conditioner, it’s likely that you’ve heard of the Arctic King brand. This is an excellent choice for your home, as it is a reliable, trusted brand with decades of experience.

However, if you have any questions or concerns, you’re probably wondering what to do next. The good news is that there are lots of helpful resources available online to assist you with troubleshooting and product maintenance.

Arctic King Air Conditioner Troubleshooting Guide

Before calling the professionals, try to troubleshoot your Arctic King Air Conditioner.

Arctic King Air Conditioner Troubleshooting

You’ll be surprised at how simple most of the fixes are. Many problems can be resolved without calling in a professional or buying expensive parts or tools.

While professional help is always appreciated, most issues are very basic and can be fixed on your own with a little time and effort. Most of the time, common faults are easy to spot and relatively simple to fix.

Arctic King AC Not Blowing Cold Air

You notice that your air conditioner isn’t blowing air that is as cool as it used to be. Or, you power on your system, but nothing happens at all. Both of these problems could come from a clogged air filter.

If your system’s air filter is not functioning properly, it will struggle to pull in the cool air that it needs to send to your home.

Leaking or Low Refrigerant

The problem of leaking or low refrigerant is that it reduces the cooling capacity of the air conditioner. So instead of receiving cold air, you will receive warm air.

If your air conditioner does not blow cold air, the first thing that you need to do is check if the refrigerant is leaking or low. This can be done by checking the pressure of the refrigerant using a pressure gauge.

If the pressure is low, then there is a possibility that the refrigerant is leaking. If the pressure is normal, then the problem could be with the compressor or the air conditioner itself.

Clogged Filter

If your AC filter is not clean, then the airflow will be restricted, making it difficult for your AC to blow cold air. It will also reduce the efficiency of your AC, making it more expensive to run.

It is not uncommon for many air conditioner system owners to forget to change the air conditioner filter of the system. This is seen more often than not during summer.

If you have a central air conditioner, check the return air vents to see if your filter is clogged, dirty or dysfunctional. Changing the filter of the system will compel it to work smarter, suck in more cool air and help it to function at peak efficiency.

Replace the old filter with a new one.

Evaporator Coil or Condenser Issue

Your air conditioner may be having a hard time cooling your home or office space because the evaporator or condenser coils may be frozen.

The evaporator coil and condenser coil are made up of aluminum and copper tubing and metal fins designed to promote quick heat transfer. To keep the coils from freezing, refrigerant circulates through the coils.

If the coils are frozen, your AC will have a hard time blowing cold air. The problem is likely to be caused by either a loss of refrigerant or a problem with the circulation fan.

Dirty coils cause the evaporator coil or condenser coil to operate at a higher temperature, which reduces the efficiency of the system, making it work harder to cool the home.

If the evaporator or condenser coils are dirty, use a soft brush to remove any foreign matter or dirt from the coils. If the coils are excessively dirty, you can use a no-rinse coil cleaner.

After cleaning the coils, turn on the air conditioner and check if it is blowing cool air.

Blocked or Clogged Registers

As it goes without say, the cooling process of your air conditioner is totally dependent on how the air moves and flows through the air vents and registers.

If the registers are blocked or clogged, air will not flow through the registers. Possibly, if the registers are blocked or clogged, not enough air will flow through the registers causing the cooling process to be affected causing the AC not to blow cold air.

If you find that your AC is not blowing cold air due to blocked or clogged registers, it is advisable that you clean or vacuum the registers and other areas that are affected.

Thermostat Issue

The first thing to check when you have an AC unit that is not blowing cold air is whether the thermostat is set properly. The thermostat controls the temperature of the air inside the AC unit. If the thermostat is set too high, the AC unit will not turn on. If the thermostat is set too low, the AC unit will not turn off.

If the thermostat is set properly and the AC unit is still not blowing cold air, there may be a problem with the AC unit itself. The AC unit may need to be cleaned or repaired.

See also  6 Reasons Why Window AC Won't Turn ON - Let's Fix It

The main way how you can get your AC working again is by checking the thermostat. If it’s not working properly, you can’t get your desired temperature. Check the batteries first and then the settings. If the batteries are fine, set the dial to “cool” and lower the temperature setting.

Arctic King AC Compressor Not Running

If the Arctic King AC compressor does not turn on, there are a few things that you can check. Make sure that the AC is plugged in and that the breaker has not been tripped. If the AC is plugged in and the breaker is not tripped, then the problem may be with the AC itself.

Dirty Coil And Filters

If the air conditioner compressor is not running, there are a few things that could be the issue. The most common issue is that the coil and filters are dirty and need to be cleaned.

If an air conditioner’s air filter is dirty, the air conditioner will consume a large amount of energy to operate. The air conditioner will also not function properly if the evaporator coil or condenser coil is covered with dust or debris.

Check that the air filter is in good condition, clean and not clogged. This will weaken its performance, causing it to run for longer than needed which could burn out its motor or lead to premature failure.

Keep the area around your air conditioner clean and free of debris for proper airflow.

Capacitor And Starter Relay Problems

The capacitor is a small, cylindrical device that is located near the compressor and helps the unit start up. The starter relay is a small box-like device that is located near the capacitor. These two devices work together to help the compressor start up.

If either one of these devices is not working properly, the compressor will not start up.

If your AC air conditioner is not running, the capacitor may be failing. If your Central AC air conditioner is not running and you hear a humming sound, the capacitor is most likely the problem and you should consider replacing it. If your AC does not start and you smell burning, this is also a sign of a failing capacitor.

Faulty Compressor

If the compressor is not running, then the air conditioner will not be able to cool the air. The compressor is the heart of the air conditioner, and if it is not working, then the air conditioner will not be able to function.

There are a few things that can cause the compressor to stop working, and the most common reason is that the compressor is dead.

Power Issues

If your air conditioner’s fan in the central unit is running but the compressor isn’t turning on, it could indicate that a fuse or circuit breaker is blown. This can be easily identified by tracing the wires leading to and coming from both the outdoor and the indoor units.

If they terminate at a single point, this would suggest an overcurrent protection mechanism has been activated to safeguard the wiring system from overheating.

Arctic King Air Conditioner Won’t Turn ON

There are several things that can cause your air conditioner not to turn on. First, check to make sure that the unit is plugged in. Next, check to see if the circuit breaker has been tripped. Finally, check to see if there is a problem with the compressor.

Thermostat Problem

There are a few things that could be causing your Arctic King air conditioner to not turn on. The most common issue is a bad thermostat. This can be caused by a variety of things, such as a loose wire or a dead battery.

It is possible that your Arctic King air conditioner is not working because the thermostat is bad. You can try replacing the batteries in the thermostat, but if that doesn’t work, you may need to replace the thermostat itself.

Tripped Circuit Breaker

If the circuit breaker of your Arctic King Air Conditioner is tripped or blown, it can cause the unit to fail to turn ON. Check the breaker box to see if the breaker has been tripped and reset it.

If the breaker trips again, you may have a problem with the wiring in your home. You should contact an electrician to check the wiring and make any necessary repairs. If the fuse is blown, you will need to replace it with a new one.

Blown Fuse

First, check to make sure the fuse is not blown. If the fuse is blown, replace it with a new fuse of the same amperage. If the fuse blows again, there may be a short circuit in the air conditioner.

Clogged Air Filter

If your air conditioner will not turn on, it may be because the air filter is clogged with dirt and debris. To clean the air filter, first turn off the power to the air conditioner.

Then remove the air filter and rinse it with water. Allow the air filter to dry completely before replacing it. If the air filter is still clogged, you may need to replace it.

AC Motor Failure

See also  Mitsubishi Mini Split Troubleshooting Guide - Let's Fix It

The Arctic King air conditioner may fail to turn on due to a failed AC motor. The AC motor is responsible for powering the air conditioner’s compressor.

If the AC motor fails, the compressor will not be able to operate, and the air conditioner will not be able to cool the air. To repair this problem, the AC motor will need to be replaced.

Arctic King Window Air Conditioner Not Cooling

There are a few reasons why your Arctic King window air conditioner may not be cooling. The most common reason is that the air conditioner is not properly sized for the space it is cooling.

If the air conditioner is too small, it will not be able to remove enough heat from the air to keep the space cool. Another reason why the air conditioner may not be cooling is that the filters are dirty or clogged. The filters need to be replaced or cleaned on a regular basis to keep the air conditioner operating properly.

Dirty air filter

If the air filter is dirty, the air conditioner will not be able to circulate cold air properly. Clean or replace the air filter.

Incorrectly sized unit

If the air conditioner is too small for the room, it will not be able to cool the room properly. Make sure to choose the correct size unit for the room.

Thermostat not set low enough

The air conditioner will not cool the room if the thermostat is not set low enough. Set the thermostat to the desired temperature.

Fan not running

The air conditioner will not be able to circulate cold air if the fan is not running. Make sure the fan is turned on.

Air conditioner is not level

The air conditioner will not work properly if it is not level.

Arctic King Air Conditioner Keeps Turning Off

The most common cause of an air conditioner shutting off on its own is a problem with the on/off switch. If this switch becomes damaged or loose, it can cause the unit to turn off on its own.

Another common cause of this problem is a tripped circuit breaker. If the circuit breaker trips, it can cause the unit to turn off on its own.

Another common cause of this problem is a faulty thermostat. If the thermostat is not working properly, it can cause the air conditioner to turn off on its own. Finally, if the air conditioner is not getting enough air flow, it can also cause the unit to turn off on its own.

The air conditioner is not big enough to cool the space. When an air conditioner is too small for the space it is cooling, it will run constantly and turn off frequently.

The air conditioner is not level. An air conditioner needs to be level in order to work properly. If it is not level, it will turn on and off frequently.

The air conditioner is not getting enough air. If the air conditioner is not getting enough air, it will turn on and off frequently.

Dirty Filter.  One of the most common reasons why your air conditioner may be shutting off is because the filters are dirty. When the filters are dirty, the air conditioner has to work harder to push air through the system, and this causes it to overheat and shut off.

The air conditioner is low on refrigerant.  Another common reason why your air conditioner may be shutting off is that there is a refrigerant leak. When the refrigerant level gets low, the air conditioner has to work harder to cool the air, and this causes it to overheat and shut off.

The air conditioner is overheating. An overheating air conditioner will turn on and off frequently.

Arctic King Air Conditioner Leaking Water

If your air conditioner is leaking water, it is most likely a problem with the AC unit itself and not the house’s plumbing. Here are a few reasons your air conditioner may be leaking water:

If your air conditioner is leaking water, it is most likely a problem with the AC unit itself and not the house’s plumbing. Here are a few reasons your air conditioner may be leaking water:

1. Clogged or Dirty Air Filter

One of the most common reasons your air conditioner may be leaking water is a clogged or dirty air filter. A dirty air filter can cause your AC unit to work harder than necessary to cool your home, which can lead to water buildup and leaks.

2. Frozen Evaporator Coils

Another common reason for water leaks from your AC unit is frozen evaporator coils. When the coils become frozen, they can no longer absorb heat, causing water to condense and leak out.

3. Leaking Refrigerant

If your AC unit is leaking refrigerant, it can also lead to water leaks.

4. Low Water Pressure

If your home has low water pressure, it can cause water to pool up and leak out of your AC unit. If you have low water pressure, contact a licensed plumber to help fix it.

5. Leaking Drain Pipes

If your AC drain pipe is leaking, you may notice water leaking from your AC unit. If this is the case, you may want to invest in a new condenser.

See also  6 Reasons Why Window AC Control Panel Not Working - Let's Fix It

Reset Arctic King Air Conditioner

To reset your Arctic King air conditioner remote control, first unplug the unit from the wall outlet. Next, find the reset button on the back of the remote. Press and hold this button for three seconds. The unit should now be reset and the remote should be working again.

Another method

Press the “Reset” button on the air conditioner. The location of the button can vary depending on the model. The button should be near the air filter or power cord. If the unit is still not working, check for a blown fuse or a tripped circuit breaker.

Arctic King Air Conditioner Control Panel Not Working

The air conditioner control panel is not working for a variety of reasons. The most common reason is that the unit is not receiving power. Check the circuit breaker to see if it has been tripped. If so, reset it and see if the unit comes on. If the circuit breaker trips again, there may be a problem with the wiring. Another reason the air conditioner control panel may not be working is that the unit may be low on refrigerant.

There are a number of reasons why an air conditioner control panel may not work properly or at all. The most common issues are listed below:

1. The control panel is not properly connected to the AC unit. Check to make sure that the control panel is firmly connected to the AC unit.

2. The fuse in the control panel has blown. Check the fuse and replace it if necessary.

3. The control panel is not powered. Check to make sure that the power cord is plugged in and that the power switch is turned on.

4. The control panel is not receiving power. Check the circuit breaker or fuse box to make sure that the circuit breaker is not tripped and that the fuse is not blown.

5. The control panel is defective. If the control panel is defective, it will need to be replaced.

Arctic King Air Conditioner Not Cooling

There are several reasons why your Arctic King air conditioner might not be cooling properly. Some of the most common reasons include:

Check Thermostat

The Arctic King air conditioner will not cool if the thermostat is not set to the correct setting. The thermostat should be set to the “cool” setting in order to cool the room.

Check that the thermostat mode is set to “COOL” and not “HEAT”.

The thermostat may be set too high, or it may be set to “cool” instead of “auto.”

Assess The Circuit Breaker

If the air conditioner is not cooling, check to see if the circuit breaker has been tripped. If it has, reset the breaker and try again. If the problem persists, contact a qualified electrician.

Clear Any Obstructions To Airflow

If the Arctic King air conditioner is not cooling properly, the first thing to check is the airflow. Make sure that there is nothing blocking the air intake or exhaust vents. If the unit is not getting enough air, it will not be able to properly cool the room.

Frozen evaporator coil

One possible reason why your air conditioner is not cooling is that the evaporator coil is frozen. When the evaporator coil is frozen, it prevents the air from being properly cooled, and as a result, the air conditioner will not work properly. There are a few things that you can do to thaw the evaporator coil and get your air conditioner working again.

To thaw the coil, you will need to turn off the air conditioner and let it thaw naturally. Once the coil is thawed, you can turn the air conditioner back on and it should start cooling properly.

Leaking refrigerant

If the air conditioner is not cooling, it may be due to a leak in the refrigerant. Check the air conditioner’s refrigerant level and, if it is low, recharge it.

If you suspect that your air conditioner is leaking refrigerant, you should contact a qualified technician to inspect the unit and repair any leaks.

Final Thoughts

We believe that by now, you may have found the solution to your problem. If not, then you may have to call the customer care number given in the user manual. You have to search for the user manual as it is given along with the unit when you buy it.

You will find it very easy to troubleshoot any problem with your Arctic king air conditioner. We have tried to give the solutions for the most common problems. Even if your problem is a little different, then also the solutions given above will work for you.

After all, it is only a matter of finding the right problem with the right solution.

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top